Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Molecules ; 26(11)2021 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-34198782

RESUMO

Fast and selective analytical methods help to ensure the chemical identity and desired purity of the prepared complexes before their medical application, and play an indispensable role in clinical practice. Mass spectrometry, despite some limitations, is an integral part of these methods. In the context of mass spectrometry, specific problems arise with the low ionization efficiency of particular analytes. Chemical derivatization was used as one of the most effective methods to improve the analyte's response and separation characteristics. The Schotten-Baumann reaction was successfully adapted for the derivatization of ESI hardly ionizable Re(VII) bis(catechol) oxochlorocomplex. Various alkyl and halogen p-substituted anilines as possible derivatization agents were tested. Unlike the starting complex, the reaction products were easily ionizable in electrospray, providing structurally characteristic molecular and fragment anions. DFT computer modeling, which proposed significant conformation changes of prepared complexes within their deprotonation, proved to have a close link to MS spectra. High-resolution MS and MS/MS measurements complemented with collision-induced dissociation experiments for detailed specification of prepared complexes' fragmentation pathways were used. The specified fragmentation schemes were analogous for all studied derivatives, with an exception for [Re(O)(Cat)2PIPA].

2.
Sci Rep ; 11(1): 12896, 2021 06 18.
Artigo em Inglês | MEDLINE | ID: mdl-34145377

RESUMO

Unconjugated bilirubin (UCB) is the end-product of heme catabolism in the intravascular compartment. Although beneficial for human health when mildly elevated in the body, when present at greater than a critical threshold concentration, UCB exerts toxic effects that are related to its physico-chemical properties, particularly affecting the central nervous system. The aim of the present study was to characterize bilirubin-10-sulfonate (ranarubin), a naturally occurring bile pigment, including determination of its mixed acidity constants (pKa*). Thanks to the presence of the sulfonic acid moiety, this compound is more polar compared to UCB, which might theoretically solve the problem with an accurate determination of the UCB pKa* values of its propionic acid carboxylic groups. Bilirubin-10-sulfonate was synthesized by modification of a previously described procedure; and its properties were studied by mass spectrometry (MS), nuclear magnetic resonance (NMR), infrared (IR), and circular dichroism (CD) spectroscopy. Determination of pKa* values of bilirubin-10-sulfonate and UCB was performed by capillary electrophoresis with low pigment concentrations in polar buffers. The identity of the synthesized bilirubin-10-sulfonate was confirmed by MS, and the pigment was further characterized by NMR, IR, and CD spectroscopy. The pKa values of carboxylic acid moieties of bilirubin-10-sulfonate were determined to be 5.02, whereas those of UCB were determined to be 9.01. The physico-chemical properties of bilirubin-10-sulfonate were partially characterized with low pKa* values compared to those of UCB, indicating that bilirubin-10-sulfonate cannot be used as a surrogate pigment for UCB chemical studies. In addition, using a different methodological approach, the pKa* values of UCB were found to be in a mildly alkaline region, confirming the conclusions of a recent critical re-evaluation of this specific issue.

3.
Electrophoresis ; 41(18-19): 1564-1567, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32640044

RESUMO

Riociguat is novel antihypertensive drug for treatment of pulmonary hypertension. As such, it is still being tested in many clinical and pharmacokinetic trials. Existing methods that determine serum riociguat and desmethylriociguat (DMR) are based solely on liquid chromatography with mass spectrometry. Therefore, we present a novel capillary electrophoresis with mass spectrometry method (CE-MS) for their determination in human serum as alternative method for ongoing trials. Complete resolution of both analytes was achieved by means of pH optimization of ammonium formate background electrolytes that are fully compatible with ESI/MS detection. Simple liquid-liquid extraction was used as sample pretreatment. The calibration dependence of the method was linear (in the range of 10-1000 ng/mL), with adequate accuracy (90.1-114.9%) and precision (13.4%). LOD and LOQ were arbitrarily set at 10 ng/mL for both analytes. Clinical applicability was validated using serum samples from patients treated with riociguat in pharmacokinetic study and the results corresponded with reference HPLC-MS/MS values. Capillary electrophoresis proved to be sensitive and selective tool for the analysis of riociguat and DMR.


Assuntos
Eletroforese Capilar/métodos , Pirazóis/sangue , Pirimidinas/sangue , Espectrometria de Massas por Ionização por Electrospray/métodos , Eletrólitos , Humanos , Limite de Detecção , Modelos Lineares , Extração Líquido-Líquido , Pirazóis/química , Pirazóis/isolamento & purificação , Pirazóis/farmacocinética , Pirimidinas/química , Pirimidinas/isolamento & purificação , Pirimidinas/farmacocinética , Reprodutibilidade dos Testes
4.
Electrophoresis ; 40(22): 2936-2945, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31520473

RESUMO

Riociguat is a novel antihypertensive drug for the treatment of pulmonary hypertension. We present electrophoretic characterization, i.e. migration behavior of riociguat and metabolite M1 as support for optimized CZE/MS assay. Fundamental separation parameters, such as peak width, symmetry, and resolution are studied in a series of ammonium formate buffers within pH range 2.60-5.61. The narrow region of peak symmetry lies close to pH 4.0 for both analytes. Accordingly, the value of resolution maximizes in a background electrolyte adjusted to pH 4.10. Basic calibration parameters estimated from CZE experiments with absorption photometric and mass spectrometric detection of riociguat and metabolite M1 were evaluated. More than three orders lower LOD was achieved with high resolution mass spectrometric detection. The observed difference in the sensitivity of both detection techniques gives priority to the utilization of CZE/MS in practice. The values of dissociation constants of riociguat and metabolite M1, pKBH , were determined from CZE measurements in lithium formate and lithium acetate background electrolytes with constant ionic strength. The value of pKBH = 4.30 ± 0.02 for riociguat corresponds well to the value already presented in the literature. According to our observation, metabolite M1 behaves like a slightly stronger base with estimated pKBH = 4.40 ± 0.02.


Assuntos
Eletroforese Capilar/métodos , Espectrometria de Massas/métodos , Pirazóis/análise , Pirazóis/metabolismo , Pirimidinas/análise , Pirimidinas/metabolismo , Humanos , Limite de Detecção , Modelos Lineares , Pirazóis/sangue , Pirazóis/química , Pirimidinas/sangue , Pirimidinas/química , Reprodutibilidade dos Testes
5.
J Chromatogr A ; 985(1-2): 513-7, 2003 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-12580520

RESUMO

A capillary electrophoresis method with UV detection was developed for the determination of 8-hydroxy-2'-deoxyguanosine (8-OHdG) in untreated urine samples. The calibration graph for 8-OHdG in urine is linear in the concentration range 10-500 mg/l. and the detection limit is 5 mg/l (17 microM). 8-OHdG was determined in urine from oncological patients treated by radiation therapy. Its concentrations relative to creatinine were found to be in the range 10-47 microg 8-OHdG/l mg creatinine (4-19 micromol 8-OHdG/mmol creatinine). The overall time of the analysis of a urine sample was less than 15 min.


Assuntos
Desoxiguanosina/análogos & derivados , Desoxiguanosina/urina , Eletroforese Capilar/métodos , Espectrofotometria Ultravioleta/métodos , 8-Hidroxi-2'-Desoxiguanosina , Calibragem , Humanos , Neoplasias/urina
6.
Electrophoresis ; 23(15): 2449-56, 2002 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12210202

RESUMO

A new analytical method for enantioselective separation of DL-amino acids derivatized by N-fluorenylmethoxycarbonyl-L-alanyl N-carboxyanhydride (FMOC-L-Ala-NCA) using capillary electrophoresis was developed. Separation parameters, such as composition and pH of the background electrolyte, and concentration of gamma-cyclodextrin (in capillary zone electrophoresis) and sodium dodecyl sulfate (in micellar electrokinetic chromatography) were optimized. The separation method was validated and it suits well for purity analysis. Detection limit of the method was 0.2% of the minor enantiomer in the major one. The level of racemization in coupling during solid-phase peptide synthesis was studied using capillary electrophoresis with gamma-cyclodextrin as a chiral selector. The anchorage of the first (C-terminal) amino acid derivative to the solid supports bearing the hydroxylic groups is the key step of the synthesis affecting the extent of its racemization. FMOC-L-phenylalanine was chosen as the suitable model amino acid derivative making it possible to study the degree of racemization of N-fluorenylmethoxycarbonyl-L-alanine-L-phenylalanine synthesized on different polymer resins, using the different condensation agents.


Assuntos
Aminoácidos/análise , Cromatografia Capilar Eletrocinética Micelar/métodos , Eletroforese Capilar/métodos , Aminoácidos/química , Fluorenos , Peptídeos/síntese química , Peptídeos/química , Estereoisomerismo , Uretana
7.
Analyst ; 127(6): 719-23, 2002 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12146901

RESUMO

A miniaturized analytical system for separating and detecting inorganic explosive residues, based on the coupling of a micromachined capillary electrophoresis (CE) chip with a contactless conductivity detector is described. The low electroosmotic flow (EOF) of the poly(methylmethacrylate) (PMMA) chip material facilitates the rapid switching between analyses of cations and anions using the same microchannel and run buffer (and without an EOF modifier), and hence offers rapid (< 1 min) measurement of seven explosive-related cations and anions. Experimental parameters relevant to the separation and detection processes have been optimized. Addition of a 18-crown-6 ether modifier has been used for separating the peaks of co-migrating potassium and ammonium ions. The ionic-explosive microchip system combines the distinct advantages of contactless conductivity detection with the attractive features of plastic CE microchips. The new microsystem offers great promise for monitoring explosive-related ions at the sample source, with significant advantages of speed/warning, efficiency, cost, or sample size.


Assuntos
Eletroforese Capilar/métodos , Íons/análise , Terrorismo
8.
Anal Chem ; 74(9): 1968-71, 2002 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-12033293

RESUMO

A microfabricated electrophoresis chip with an integrated contactless conductivity detection system is described. The new contactless conductivity microchip detector is based on placing two planar sensing aluminum film electrodes on the outer side of a poly(methyl methacrylate) (PMMA) microchip (without contacting the solution) and measuring the impedance of the solution in the separation channel. The contactless route obviates problems (e.g., fouling, unwanted reactions) associated with the electrode-solution contact, offers isolation of the detection system from high separation fields, does not compromise the separation efficiency, and greatly simplifies the detector fabrication. Relevant experimental variables, such as the frequency and amplitude of the applied ac voltage or the separation voltage, were examined and optimized. The detector performance was illustrated by the separation of potassium, sodium, barium, and lithium cations and the chloride, sulfate, fluoride, acetate, and phosphate anions. The response was linear (over the 20 microM-7 mM range) and reproducible (RSD = 3.4-4.9%; n = 10), with detection limits of 2.8 and 6.4 microM (for potassium and chloride, respectively). The advantages associated with the contactless conductivity detection, along with the low cost of the integrated PMMA chip/detection system, should enhance the power and scope of microfluidic analytical devices.


Assuntos
Eletroforese Capilar/instrumentação , Ânions/isolamento & purificação , Cátions/isolamento & purificação , Condutividade Elétrica , Eletrodos , Miniaturização , Polimetil Metacrilato
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...